Error: F_JD22F0: Log Record Encountered With Minimized Entry Data Enabled
Issue
The following capture error appears:
F_JD22F0: Log record encountered with minimized entry data enabled (minimized_entry_data='1', minimized_on_field_boundary='0'). Verify that IBM i journal attribute MINENTDTA is set to *NONE.
Environment
- HVR 6
- DB2i
Resolution
To resolve this issue, set the journal attribute MINENTDTA
to *NONE
.
Cause
This error occurs as a result of the source journal compression. HVR is incompatible with compression.`